Some links on this page are affiliate links. As an Amazon Associate, we earn from qualifying purchases — at no extra cost to you. We do not buy, test, or physically handle the products we cover; our rankings come from aggregated owner reviews, ratings and expert consensus. Commissions never change our verdicts. How we rank · full disclosure.

Stabilize the fuel, run the carburetor dry, change the oil, disconnect the battery, and start it under load for 20 minutes once a month. That routine takes about half an hour up front and 20 minutes a month afterward, and it prevents almost everything that stops a stored generator from starting. The overwhelming cause of a generator that will not run after sitting is not a worn engine — it is ethanol-blended gasoline that degraded in the carburetor while the machine did nothing.

The fuel problem, which is most of the problem

Gasoline sold across the United States is typically E10, containing up to 10% ethanol — a consequence of the federal Renewable Fuel Standard described by the EPA, with background in the EIA's biofuels explainer. Ethanol is hygroscopic: it pulls water vapor out of the air through the tank vent. Once enough water accumulates the mixture phase-separates, leaving a layer of water and ethanol at the bottom of the tank and a fuel above it that has lost octane.

Untreated, this process begins within about 30 days and is well advanced by three months. Two things follow. Water and ethanol in contact with steel and aluminum corrode both. And as the light fractions evaporate out of the carburetor float bowl, what remains is a sticky varnish that dries across the jets.

Those jets are the crux. A small-engine carburetor meters idle and low-speed fuel through passages measured in thousandths of an inch. It takes a trivial amount of varnish to block one completely, at which point the engine cranks strongly, has spark and compression, and will not fire. The owner concludes the generator is dead. It needs a carburetor clean — $90 to $200 at a small-engine shop, and the reason those shops are booked solid every hurricane season.

Prevention is a stabilizer added at fill time and a carburetor emptied before storage. That is it.

#2Star Tron Enzyme Fuel Treatment, Small Engine Formula, Gas Additive Rejuvenates and Stabilizes Fuel
Best for Long-Idle Engines
Star Tron Enzyme Fuel Treatment, Small Engine Formula, Gas Additive Rejuvenates and Stabilizes Fuel

Best for machines that already sat with old fuel, and seasonal small engines generally

  • Enzyme formula intended to disperse water and break down gum
  • Small-engine dosing on the bottle
  • Usable as both a stabilizer and a treatment for aged fuel
  • Works with ethanol-blended gasoline

Why buy it: the small-engine formula is dosed for the tank sizes generators actually have, which is where owners most often get the concentration wrong.

Check price on Amazon (paid link) Where to buy: Amazon
#3Champion Power Equipment Weather-Resistant Storage Cover for 2000 to 4000-Watt Inverter Generators
Best Storage Cover
Champion Power Equipment Weather-Resistant Storage Cover for 2000 to 4000-Watt Inverter Generators

Best for keeping dust, rodents and condensation off a stored inverter generator

  • Sized for 2,000 to 4,000-watt inverter generators
  • Weather-resistant fabric with an elasticized hem
  • Keeps dust and debris out of vents and the control panel
  • For storage, not for use while the generator runs

Why buy it: a storage cover is not a running cover — this one keeps a stored machine clean, and running under it would trap exhaust and heat.

Check price on Amazon (paid link) Where to buy: Amazon
Over-the-shoulder view of a person drilling into a timber board on a workbench, sawdust in the air, in soft early-morning light

The storage routine, step by step

  1. Fill the tank and add stabilizer at the correct dose. Full is better than partly empty, because an air space breathes moist air in and out with temperature swings. Dose by the bottle's instructions for the tank volume — over-treating is not better.
  2. Run the engine for 10 minutes so treated fuel reaches the carburetor. Stabilizer that never leaves the tank protects the tank and nothing else.
  3. Close the fuel shut-off valve and let it run until it stops. This empties the float bowl, which is where varnish forms. If your machine has no shut-off valve, drain the bowl using its drain screw, or drain the tank and run it dry. This step matters more than any other.
  4. Change the oil while the engine is still warm. Warm oil carries suspended contaminants out with it. Old oil is acidic and will pit bearing surfaces over a long layup. Replace the filter if the engine has one.
  5. Deal with the spark plug. For storage over six months, remove the plug, put a teaspoon of clean engine oil into the cylinder, pull the recoil slowly a couple of times to spread it on the bore, and refit the plug. This prevents cylinder-wall rust in humid storage.
  6. Disconnect the starting battery on an electric-start machine and keep it on a maintainer, or at minimum charge it every three months. A lead-acid battery left discharged over a winter sulfates and will not recover.
  7. Clean the machine. Wipe off oil and fuel residue, clear debris from the cooling fins and the air intake, and check the air filter.
  8. Block the exhaust and intake loosely — a rag or a purpose-made plug — against mice, wasps and dirt daubers. Write yourself a note, because a forgotten rag in an exhaust is its own problem.
  9. Store it dry, off the floor, under a breathable cover. Concrete wicks moisture; a pallet or a shelf stops it. Avoid sealed plastic sheeting, which traps condensation against the metal.

Full tank or empty tank?

Storage periodTankCarburetorReasoning
Under 30 daysFull, treatedLeave itFuel is still good; condensation is the only risk
1–6 monthsFull, treatedRun dryStabilizer holds the tank; the bowl is the vulnerable part
6–12 monthsFull, treated, or drainedRun dryEither works if the fuel is treated at fill
Over 12 monthsDrain completelyRun dry and drain the bowlNo stabilizer is indefinite; remove the fuel
Seasonal, exercised monthlyFull, treatedRefreshed by the monthly runThe best case — fuel never sits long enough to degrade

Note the trap in the "drain it" advice: draining the tank alone is not enough, and is arguably worse than leaving treated fuel in. The tank empties, the bowl does not, and the small volume left in the bowl evaporates completely and leaves the heaviest varnish deposit of all. If you drain, drain the bowl too.

Low-angle view of a person drilling into a timber board on a workbench, sawdust in the air, in soft early-morning light

The monthly exercise run

This is the single most valuable habit in generator ownership, and the one most owners skip.

Run the machine under a real load — a couple of space heaters, a shop vacuum, work lights, anything that puts a genuine several hundred watts through it — for about 20 minutes, once a month. A 30-second no-load run is worse than nothing: it introduces fuel and condensation into a cold engine and never reaches the temperature that drives moisture back out.

Twenty minutes under load does four things. It pulls fresh, treated fuel through the whole fuel path. It brings the crankcase hot enough to evaporate accumulated water. It charges the starting battery. And most importantly, it tells you the generator works — in daylight, in fair weather, when a fouled plug or a flat battery is a fifteen-minute errand instead of a crisis.

If you own a dual fuel machine, running the monthly exercise on propane keeps the engine exercised while leaving no varnish behind at all. That is a genuine practical argument for dual fuel that has nothing to do with fuel cost — see best dual fuel generators.

Bringing a stored generator back

  1. Check the oil level and condition before anything else. Top up or change if it looks dark or smells of fuel.
  2. Reconnect and check the battery, or charge it if it has been sitting.
  3. Remove any exhaust or intake plugs. Inspect for nests — mice and wasps are the second most common cause of a stored machine failing.
  4. Fill with fresh gasoline. If old fuel is in the tank, drain it and dispose of it at a household hazardous-waste facility; do not pour it into a car.
  5. Open the fuel valve, wait a minute for the bowl to fill, and start.
  6. Run at no load for five minutes, then apply load progressively and confirm output at the receptacles.
  7. If it cranks but will not fire, the odds heavily favor a blocked carburetor jet rather than an engine fault. That is a cleaning job, not a replacement.
Store it in the garage; never run it there. A portable generator emits as much carbon monoxide as hundreds of cars, and the CPSC links more than 100 US deaths a year to generator CO. It is colorless and odorless, so there is no warning. Every run — including the monthly exercise run — happens outdoors only: never in a garage, basement, shed or under a carport, and an open garage door does not make an enclosed space safe. Site it at least 20 feet from the house with the exhaust pointed away from doors, windows and vents, and fit CO alarms on every level indoors. See the CPSC Carbon Monoxide Information Center. Store gasoline in approved containers away from living space and ignition sources; most US fire codes limit residential quantities and local rules differ, so check with your fire marshal.
Close-up detail of the material being worked in a power tools & workshop project, in soft early-morning light

Five storage mistakes

Leaving untreated fuel in it. The defining mistake of the category, and the reason small-engine shops are full every September.

Draining the tank but not the bowl. The bowl is where the varnish forms. Half the job leaves the worse half undone.

Brief no-load starts instead of a real exercise run. A cold 30-second run adds moisture and removes none.

A sealed plastic cover. Trapping condensation against metal for six months causes exactly the corrosion you were trying to prevent. Use a breathable cover.

Storing it on a concrete floor. Concrete wicks ground moisture into whatever sits on it. A pallet or a low shelf costs nothing and solves it.

Where to go next

If the machine is new, start with how to break in a new generator. For fuel planning and consumption figures, see how much gas a generator uses. The propane route that avoids most of this is in best dual fuel generators, and machine selection in best generators for home backup. Everything sits under the power tools and workshop hub.

We never buy or physically handle the equipment we write about — this guidance is drawn from manufacturer service documentation and aggregated owner experience, and your model's manual overrides any general figure here. The method is on how we rank. Product links are affiliate links; they earn us a small commission at no cost to you and never change a recommendation.

Straight Answers

Frequently Asked

How do you store a generator long term?

Add a fuel stabilizer to a full tank and run the engine for 10 minutes so treated fuel reaches the carburetor, then close the fuel shut-off valve and let the engine run until it stops so the float bowl is empty. Change the oil while the engine is warm, remove or disconnect the starting battery and keep it on a maintainer, wipe the machine down, and store it in a dry place off the floor with a breathable cover. Then start it under load for 20 minutes once a month. That monthly run is the step that actually keeps it working.

Should you drain the gas out of a generator for storage?

For storage longer than about six months, yes — or better, do both. Drain the tank, then close the fuel shut-off and run the engine until it stops so the carburetor bowl empties too. Draining the tank alone leaves fuel in the bowl, and the bowl is where the damage happens, because that small volume evaporates and leaves varnish across the jets. For shorter storage, a full tank of stabilized fuel is preferable to a partly empty one, because an air space in the tank encourages condensation and rust.

How often should you start a stored generator?

Once a month, under a real load, for about 20 minutes. Not a 30-second no-load run — that does more harm than good, because it wets the cylinder without ever reaching operating temperature to drive off condensation. A proper monthly exercise run circulates fresh fuel through the carburetor, brings the engine hot enough to evaporate water in the crankcase, charges the starting battery on electric-start machines, and tells you the machine works while you still have time to fix it.

Why will a stored generator not start?

Stale fuel, in the great majority of cases. US pump gasoline is typically E10, containing up to 10% ethanol, and ethanol absorbs water from the air and begins separating within about 30 days. The varnish it leaves behind blocks the pilot jets in a small carburetor — passages measured in thousandths of an inch — so the engine cranks but never fires. Next most common is a flat starting battery, then a fouled spark plug, then old oil that has thickened. Almost none of these are engine faults, and all are preventable with a storage routine.

Can you store a generator in the garage?

Yes for storage — never for operation. A dry garage, off the concrete floor on a pallet or a shelf, with a breathable cover, is a good storage location. What you must never do is run it there. A portable generator emits as much carbon monoxide as hundreds of cars, and an attached garage fills faster than an open door can clear it. Store the machine in the garage, then wheel it at least 20 feet from the house before starting it. Store fuel in approved containers, away from ignition sources and away from living space.